Serial Port |
Interface | 4 * RS-485/RS-422 |
Connector | Ternimal blocks |
Baud Rate (Data Rate) | 600~460800 (bps) |
Data Bits | 7, 8 |
Validation modes | none, odd parity, even parity |
Stop Bit | 1, 2 |
Flow Control | Auto Flow Control |
Signals | RS422 : Tx+, Tx-, GND, Rx+, Rx- |
RS485: Data A (+), GND, Data B (-) |
Fast Ethernet Port |
Standard | IEEE 802.3 10BASE-T standard |
IEEE 802.3u 100BASE-TX standard |
IEEE 802.3x Full-duplex flow control |
Isolation protection | 1.5KV isolation protection |
Connector | RJ45 |
Hardware |
Copper Port | 10/100Mbps, RJ45 interface; adaptive MDI / MDIX |
Serial Port | RS-422/RS-485 |
DIP Switch | Reset system to factory default |
LED Indicators | System: Power x 1 |
10/100BASE-TX Port: Link/Active x 1 |
RS422/RS485 Serial Port: TX (Transmit) x 2, RX (Receive) x 2 |
Dimension (W x D x H) | 207mm x 112mm x 34.2mm |
Power Input Connector | 2-contact terminal block connector DC power (9-36V) * |
Power Consumption | 66mA@12V |
Mechanical | Metal |
Installation | Wall-mount kit |
Software parameters |
Network Protocols | ICMP, IPv4, IP, ARP, TCP, UDP, DHCP, DNS, HTTP, RFC2217 |
IP acquisition method | Static IP/DHCP |
DNS | Support |
User configuration | Web configuration |
Simple transparent transmission | RealCom,TCP Server/TCP, Client/UDP, Pair_Connection |
RealCom | Support working modes such as Maiwe, Moxa, Kanghai, etc |
Modbus | Support Modbus RTU/ASCII to Modbus TCP(Master & Slave Mode) |
Support Modbus Over TCP |
Modbus TCP to Modbus RTU |
Serial port packaging mechanism | Time and length can be set; the default value changes |
according to the bit rate; the maximum packing length is 1460bytes. |
TCP Server Connection | Support up to 8 TCP connections |
Network Cache | Send: 16Kbyte; Receive: 16Kbyte; |
Serial Buffer | Send: 1.5Kbyte; Receive: 1.5Kbyte; |
Heartbeat Package | TCP Keepalive |
Registration package | Custom registration package |
Average Transmission | <10ms |
Supporting Software | Network Configuration Tool, VirtualCOM, MWView, MaxView |
Reliability |
ESD | ±8kV(contact); ±15kV(air) |
Surge | Power supply: ±2kV / common mode, ±2kV/ differential mode |
RS485/ 422: ±2kV / common mode, ±2kV/ differential mode |
Network port: ±6kV/ common mode, ±2kV/ differential mode |
EFT | Power supply: ±2kV Communication port: ±2kV |
Standards Conformance |
Standards Compliance | IEEE 802.3 10BASE-T standard |
IEEE 802.3u 100BASE-TX standard |
IEEE 802.3x Full-duplex flow control |
EIA/TIA RS422/485 |
Regulatory Compliance | FCC, RoHS, CE |
Environment |
Temperature | Operating: -40 +85 degrees C |
Storage: -40 +85 degrees C |
Humidity | Operating: 5-95% (non-condensing) |
Storage: 5-95% (non-condensing) |